| Meaning of the first digit: 6 | Dust-tight. No ingress of dust is permitted under the applicable test conditions. | Dust-tight. No ingress of dust is permitted under the applicable test conditions. | Both ratings provide the same highest dust-protection level in the IP code. Consider the installation environment, such as airborne dust, powders, or debris. |
| Meaning of the second digit | 5: Protection against water jets from any direction under the specified test conditions. | 7: Protection against the effects of temporary immersion in water under the specified test conditions. | The second digit describes different water tests. An immersion rating does not automatically mean the enclosure has passed the water-jet test. |
| Typical water exposure to assess | Washdown, splashing, or water jets, subject to the limits of the IEC test. | Accidental or temporary immersion, within the specified depth and duration conditions. | Choose the rating that matches the actual exposure. Neither rating alone guarantees suitability for every cleaning method, chemical, or operating condition. |
| Immersion test reference | IP65 does not specify an immersion test. | IPX7 testing generally involves temporary immersion up to 1 m for 30 minutes, subject to the applicable IEC 60529 test conditions and enclosure configuration. | Confirm the test conditions and product documentation rather than interpreting IP67 as protection at any depth or for unlimited time. |
| Is IP67 automatically better than IP65? | Provides a defined water-jet protection level. | Provides a defined temporary-immersion protection level. | Not necessarily for every use. IP67 does not, by itself, confirm that an enclosure passed the IPX5 water-jet test. Where both exposures matter, look for a rating or test evidence covering both. |
| Display assembly details to verify | Check whether the stated rating applies to the complete display, the front panel only, or another specified part of the enclosure. | Ask whether the rating was tested with the unit installed and with its intended cables, connectors, glands, covers, and mounting hardware in place. |
| Other environmental requirements | An IP code addresses ingress protection, not every environmental or mechanical property. | Separately assess temperature range, humidity, corrosion resistance, impact resistance (IK rating), vibration, sunlight readability, and cleaning-agent compatibility as needed. |
| Practical selection guide | Consider when dust-tight protection and resistance to water jets are relevant to the application. | Consider when dust-tight protection and temporary immersion protection are relevant to the application. | Base the choice on the expected exposure and the exact installation. Request the applicable test report or technical documentation for the complete configuration. |
| Important note | IP ratings are defined by IEC 60529 and describe protection provided by an enclosure under specified test conditions. They should not be treated as a guarantee against all dust, water, cleaning, or field-installation conditions. |