| Acoustic Performance | Approx. Rw 30–35 dB | Approx. Rw 36–42 dB | Approx. Rw 43–50 dB | Laboratory test report for the complete window assembly, not glazing alone |
| Sound-Test Standard | May provide basic laboratory data | Testing commonly aligned with ISO 10140 or ASTM E90 | Independent testing aligned with ISO 10140, ASTM E90, or equivalent national standards | Test date, specimen size, installation method, frequency spectrum, and weighted rating |
| Aluminium Frame Design | Standard hollow aluminium profiles | Thermally improved profiles with multiple chambers or reinforced sections | Deep, reinforced, thermally broken profiles engineered for high acoustic and weather performance | Profile depth, wall thickness, thermal break width, reinforcement, and corner construction |
| Glazing Configuration | Double glazing with standard air or gas cavity | Asymmetric double glazing with laminated acoustic glass | Acoustic laminated glass, asymmetric panes, wide cavity, or high-performance triple glazing | Glass thickness, interlayer type, pane asymmetry, cavity width, and gas filling |
| Typical Glass Thickness | 4–6 mm per pane | 6–10 mm, often including laminated glass | 8–12 mm acoustic laminated glass combined with asymmetric glazing | Declared glass build-up and certified acoustic result for the selected configuration |
| Opening Type | Sliding or basic casement systems | Multi-point casement, tilt-and-turn, or lift-and-slide options | High-seal casement, tilt-and-turn, fixed-light combinations, and acoustically optimized sliding systems | Air leakage risk, gasket compression, hardware adjustment, and tested opening size |
| Air Permeability | Basic sealing; performance varies by system | Typically Class 3–4 under EN 12207 when properly fabricated | Class 4 under EN 12207 is commonly targeted for high-performance systems | Air-permeability classification and test pressure for the complete window |
| Watertightness | Basic weather resistance | Commonly Class 6A–8A under EN 12208 | Class 9A or higher may be available depending on system and size | Water-tightness class, test pressure, drainage design, and installation conditions |
| Thermal Performance | Typical Uw above 2.0 W/m²K | Typical Uw around 1.3–2.0 W/m²K | Typical Uw around 0.8–1.3 W/m²K with suitable glazing and spacers | Uw value for the actual window size, glazing, spacer, frame, and installation reference |
| Thermal-Break Technology | May use non-thermal or limited thermal separation | Polyamide thermal barrier commonly used | Wider thermal barriers, insulated chambers, and low-conductivity spacers may be specified | Thermal-break material, width, continuity, and condensation-control details |
| Sealing System | Single or basic EPDM gasket arrangement | Multi-point locking with dual or triple gasket seals | Continuous multi-seal system with acoustically optimized compression and corner joints | Gasket material, number of seals, welded or vulcanized corners, and adjustment procedure |
| Wind Resistance | Suitable for moderate exposure and smaller openings | Commonly Class C3–C5 under EN 12210, depending on design | Higher resistance classes available for reinforced systems and engineered sizes | Wind-load calculation based on building height, location, exposure, and window dimensions |
| Maximum Tested Size | Usually smaller standard modules | Medium and large modules subject to glass and hardware limits | Large fixed, casement, and lift-and-slide units subject to engineering approval | Tested dimensions, sash weight limit, deflection criteria, and delivery restrictions |
| Certification Documentation | Product datasheet and basic compliance documents | Performance reports for acoustic, air, water, and wind resistance | Third-party reports, declarations of performance, engineering calculations, and installation manuals | Document traceability, applicable standard, laboratory accreditation, and tested configuration |
| Customization Options | Limited colors, glass types, and hardware choices | Multiple powder-coating colors, glass combinations, and opening styles | Project-specific acoustic, thermal, security, solar-control, and finish specifications | Whether customization is covered by certification or requires re-testing |
| Finish Durability | Standard powder coating for general environments | Architectural-grade powder coating or anodized finish | Marine-grade or enhanced coating systems available for demanding climates | Coating thickness, pretreatment, applicable durability class, and warranty conditions |
| Installation Support | General fitting instructions | Installation drawings and recommended sealing details | Project-specific shop drawings, acoustic perimeter-sealing details, site guidance, and commissioning support | Interface between frame, wall, reveal, sill, perimeter sealant, and ventilation strategy |