| 1 | Application and pump type | Pumped medium, gas or liquid, operating temperature, solids or condensate content, and duty cycle | The proposed design is suitable for the actual medium and process conditions, not just a similar application. | Completed application questionnaire and written technical proposal |
| 2 | Capacity at the duty point | Flow or pumping speed, with the corresponding inlet and outlet pressure; state units such as m³/h, L/min, or Pa | Compare capacity at the required operating point, rather than relying on a maximum or free-air rating alone. | Performance curve or test data with stated test conditions |
| 3 | Pressure or vacuum range | Required inlet pressure, discharge pressure, pressure differential, and ultimate pressure where relevant | Check that the stated range covers normal operation, start-up, and any specified peak condition. | Model-specific operating envelope and pressure or vacuum test report |
| 4 | Power and operating costs | Motor rated power in kW, supply voltage and frequency, running current, and input power at the duty point | Verify that electrical ratings match the site supply and compare power consumption at equivalent operating conditions. | Motor nameplate data and, where available, measured input-power results |
| 5 | Materials and corrosion resistance | Materials for casing, impeller or rotor, shaft, wetted parts, and coatings | Match materials to the medium, temperature, and corrosion or abrasion risks; confirm any material substitutions in writing. | Bill of materials, material specifications, and coating details |
| 6 | Seals, leakage, and lubrication | Seal type, leakage limits if specified, lubrication method, lubricant type, and maintenance intervals | Confirm compatibility with the pumped medium and whether oil carryover, leakage, or contamination is acceptable. | Seal and lubrication specifications plus maintenance instructions |
| 7 | Performance testing and acceptance | Test method, measured operating point, tolerances, and pass/fail criteria | Agree the test standard and acceptance limits in the purchase contract. ISO 21360-1 is relevant to vacuum-pump performance measurement; ISO 9906 applies to specified rotodynamic pump hydraulic acceptance tests. | Factory test report showing instrument readings and test conditions |
| 8 | Safety and electrical protection | Guarding, emergency or overload protection, enclosure rating, and applicable electrical documentation | Specify site safety and environmental requirements; confirm the declared protection rating suits the installation conditions. | Risk and safety documentation, wiring diagram, and enclosure-rating details where applicable |
| 9 | Controls and installation | Control method, required sensors, connection sizes, mounting dimensions, weight, and allowable installation orientation | Check interfaces against the existing system and identify any required valves, filters, silencers, or control equipment. | General arrangement drawing, connection schedule, and control diagram |
| 10 | Warranty, service, and spare parts | Warranty period and exclusions, recommended spare-parts list, delivery lead times, and service response arrangements | Clarify warranty start date, wear-part coverage, parts availability, and the documentation supplied with the pump. | Written warranty terms, spare-parts list, and operation and maintenance manual |