| 1. Calculate continuous load torque | Torque required during normal, sustained operation. | A 120 N tangential force acting at a 0.05 m radius requires 6 N·m: torque = force × radius. | Include friction, gravity, and process loads. Compare the calculated value with the motor’s continuous torque rating at the actual operating conditions. |
| 2. Identify peak torque events | Short-duration demands such as acceleration, startup, or overcoming a temporary load. | For example, a mechanism may need 16 N·m for 0.5 seconds during acceleration, while its running torque is 6 N·m. | Check both the peak torque magnitude and its permitted duration. A peak rating is not a continuous operating rating. |
| 3. Match motor ratings to the duty cycle | How long the motor runs at each torque level, including rest or cooling periods. | A repeating cycle could include 6 N·m for 8 seconds and 2 N·m for 2 seconds. The average thermal load depends on the full cycle, not peak torque alone. | Use the manufacturer’s duty-cycle and thermal data. Confirm that winding temperature remains within its specified limit for the real operating cycle. |
| 4. Allow for a practical sizing margin | Uncertainty in load estimates, friction, wear, and operating conditions. | With a 6 N·m continuous load and a 25% design margin, the target continuous rating is 7.5 N·m. | Treat the margin as an engineering allowance, not a substitute for measuring the load or checking thermal performance. |
| 5. Check torque at the required speed | The torque-speed curve and the speed needed at the motor shaft or output. | Mechanical power is P = T × ω. At 8 N·m and 1,500 rpm, the approximate mechanical power is 1.26 kW. | Verify that the motor can deliver the required torque at the target speed; available torque can decrease as speed rises. |
| 6. Include inertia and acceleration needs | Load inertia, acceleration time, and any transmission ratio. | Acceleration torque is related to inertia and angular acceleration: T = J × α. A shorter acceleration time generally requires more torque. | Calculate the reflected inertia at the motor shaft and include acceleration torque alongside friction and process torque. |
| 7. Validate the complete motor and drive system | Drive current, supply voltage, cooling, mounting, and peak-torque limits. | Example check: a motor rated for 8 N·m continuous and 20 N·m peak for 2 seconds exceeds a 7.5 N·m continuous target and a 16 N·m, 0.5-second peak demand, subject to drive and thermal limits. | Confirm that the controller can supply the required current and that the motor’s specified peak duration, cooling method, and installation conditions match the application. |