| Typical installation | Inside a building, such as from a building entrance to a communications room or subscriber outlet. | Suspended between a distribution point and a building, using a support wire or self-supporting construction as specified. | Buried directly in soil where the cable is designed and approved for that method. | Pulled through an underground or indoor duct or conduit that provides a physical pathway. | Runs that pass from an outdoor area into a building, where one cable is intended to serve both environments. |
| Jacket and environmental protection | Typically uses a flame-rated indoor jacket. Outdoor UV and moisture protection may not be provided. | Typically uses a UV-resistant, weather-resistant jacket; some designs include water-blocking materials. | Typically includes a moisture-resistant construction and may include armor or other rodent protection. | Needs a jacket suitable for the duct environment; water-blocking features may be useful where water can enter the pathway. | Uses a jacket designed for the stated indoor and outdoor conditions, including the required fire-performance rating indoors. |
| Support and tensile loading | Usually supported by building pathways, clips, or trays. Do not use the optical cable as a structural support. | Must be rated for the span, sag, wind, and installation tension. Use the specified messenger or self-supporting design. | Burial depth, backfill, and mechanical protection should follow local requirements and the cable instructions. | Pulling tension and sidewall pressure must stay within the cable manufacturer's limits. | Check both outdoor pulling or support requirements and indoor routing requirements for the complete cable route. |
| Fire and building-code considerations | Choose the applicable indoor rating, such as riser or plenum where required by the building pathway and local code. | Outdoor-rated construction alone may not meet indoor fire requirements. Check what is required at the building entrance. | Outdoor-rated construction alone may not meet indoor fire requirements. Check what is required at the building entrance. | Determine whether the duct is indoors, outdoors, or passes through a fire-rated space; select the required rating. | Verify the specific listing and permitted use for both outdoor exposure and the indoor spaces the cable enters. |
| Fiber and bend selection | Single-mode fiber is common for access links. Bend-insensitive fiber can help in tight indoor routing when compatible with the system. | Single-mode fiber is common for access links. Check the minimum bend radius during installation and after installation. | Single-mode fiber is common for access links. Select fiber and construction to suit route length, handling, and splice requirements. | Choose fiber compatible with the optical link budget and ensure the cable can be pulled without exceeding its bend limits. | Confirm that the fiber type, connectors, and splice components are compatible throughout the full link. |
| Main advantages | Designed for building interiors and can be easier to route and terminate in indoor pathways. | Designed for exposed spans and outdoor weather when installed within its specified limits. | Designed to withstand underground conditions when the cable and installation method are correctly matched. | The pathway can protect the cable and may make replacement or upgrades easier if the duct is suitable. | Can reduce the need for a cable transition at the building entrance when its ratings cover the entire route. |
| Common limitations | May be unsuitable for prolonged outdoor exposure, direct burial, or aerial spans. | Requires suitable attachment points and careful span design; an indoor transition may still be needed. | More demanding installation and repair conditions; not every outdoor cable is approved for direct burial. | Conduit capacity, bends, water, and pulling distance can limit installation; the duct does not remove cable tension limits. | May cost more than a cable designed for a single environment; “indoor/outdoor” does not automatically mean plenum-rated. |
| Best fit | Choose for routes entirely inside a building when its fire rating matches the pathway. | Choose for exposed building-to-building or pole-to-building spans when the cable is rated for the span and weather. | Choose only when the route requires burial and the cable is specifically rated for direct burial. | Choose when a suitable conduit or duct is available and the cable is rated for pulling through it. | Choose for a continuous outdoor-to-indoor route only after confirming all required environmental and fire ratings. |
| Before ordering | Confirm fiber type and count, connector or splice plan, cable diameter, pathway capacity, jacket rating, operating environment, minimum bend radius, maximum pulling tension, and applicable local code. Treat cable dimensions and performance limits as product-specific rather than universal. |