| Measurement Principle | Transit-time ultrasonic measurement using two external transducers | Measures the difference in ultrasonic travel time with and against the flow direction. | Choose transit-time technology for relatively clean water and closed, full pipes. |
| Target Accuracy | Typically ±1% to ±2% of reading under specified installation and flow conditions | Accuracy depends on pipe condition, installation, flow profile, signal quality, and calibration. | For billing or custody-transfer use, request a traceable calibration certificate and confirm the applicable standard. |
| Pipe Diameter | Common clamp-on coverage: approximately DN15 to DN600; larger sizes may be available | Transducer spacing and acoustic signal strength change with pipe size. | Provide the exact outside diameter, wall thickness, liner thickness, and pipe material before ordering. |
| Pipe Material | Compatible options commonly include carbon steel, stainless steel, ductile iron, copper, PVC, and other plastics | Ultrasonic transmission varies according to acoustic velocity, wall thickness, and liner properties. | Confirm material selection in the meter menu and verify compatibility with lined or heavily corroded pipes. |
| Water Quality | Best suited to clean or moderately clean water with limited suspended solids and bubbles | Air bubbles and excessive solids can weaken or scatter the ultrasonic signal. | For aerated, slurry-like, or highly contaminated water, conduct an on-site signal test before purchase. |
| Flow Direction | Bidirectional measurement is commonly available | The meter compares upstream and downstream transit times to determine flow direction and velocity. | Select a bidirectional model when the pipeline can reverse or when return-flow monitoring is required. |
| Typical Flow Velocity | Approximately 0.01 to 12 m/s, depending on meter design and pipe conditions | The usable range is affected by signal quality, pipe diameter, fluid properties, and required accuracy. | Compare the expected minimum, normal, and maximum flow with the manufacturer’s calibrated range. |
| Pipe-Full Requirement | The pipe should remain completely full at the measurement point | Partially filled pipes can interrupt the acoustic path and cause unstable or invalid readings. | Avoid the highest point of a pipeline, free-discharge outlets, and locations where air can accumulate. |
| Straight-Pipe Installation | A representative starting point is about 10D upstream and 5D downstream; follow the meter manual | Elbows, valves, pumps, and reducers can create turbulence and an uneven velocity profile. | Use the longest available straight section and keep the sensors away from strong flow disturbances. |
| Temperature Range | Typical water applications: approximately 0°C to 80°C; wider ranges depend on transducer type | Sensor coupling, electronics, and pipe conditions change with temperature. | Specify the minimum and maximum process temperature, including short-term peaks. |
| Installation Method | External mounting with straps, rails, couplant, and adjustable transducer spacing | No pipe cutting, welding, or process shutdown is normally required. | Choose clamp-on installation for temporary surveys, retrofit projects, and non-invasive monitoring. |
| Output and Communication | Common options include pulse output, relay, 4–20 mA, RS-485, and Modbus RTU | Outputs determine how flow data can be connected to a PLC, data logger, or building management system. | Match the interface, pulse scale, isolation requirements, and communication protocol to the control system. |
| Power Supply | Common configurations include 12–24 VDC, 85–265 VAC, or battery operation | Power availability affects installation cost, operating continuity, and portability. | Use battery power for temporary measurement and a fixed supply for continuous plant monitoring. |
| Enclosure Protection | Select an enclosure rating appropriate to the environment, such as IP65 or IP67 | Dust, washdown water, condensation, and outdoor exposure can damage electronics. | Use a higher protection level for outdoor, wet, dusty, or washdown locations. |
| Display and Data Logging | Look for instantaneous flow, totalized volume, signal strength, diagnostics, and stored records | Diagnostic information helps identify poor coupling, air in the line, or an unsuitable installation point. | Choose onboard logging when readings must be reviewed without a separate data-acquisition system. |
| Verification Before Purchase | Confirm pipe data, fluid conditions, expected flow range, installation space, outputs, and calibration requirements | A suitable meter can still perform poorly if the installation point or application data is incorrect. | Request an application review or site trial when the pipe is lined, corroded, partially full, or aerated. |