| 1 | Identify the Hazardous Location | Confirm whether the risk involves flammable gas, vapor, liquid mist, combustible dust, or fibers. Review the site classification prepared by a qualified safety professional. | IEC 60079 area classification; ATEX zones; NEC Class/Division or Class/Zone classification, depending on the installation jurisdiction. | Gas or vapor: Zones 0, 1, 2. Dust: Zones 20, 21, 22. North American systems may use Class I, II, or III and Division 1 or 2. | Never select a camera from the product name alone. The camera certification must match or exceed the actual hazardous-area classification. |
| 2 | Verify the Protection Certification | Check that the certificate is issued under a recognized conformity system and that the complete marking covers the intended gas or dust environment. | IECEx certification; ATEX certification under Directive 2014/34/EU; or an applicable national certification such as an approved North American hazardous-location listing. | International projects often specify IECEx or ATEX. North American projects generally require certification accepted for the local electrical code. | Request the certificate number, marking, schedule of limitations, installation instructions, and details for all accessories connected to the camera. |
| 3 | Match the Protection Concept to the Risk | Review the protection method shown in the marking, such as flameproof enclosure, increased safety, intrinsic safety, or a combination of methods. | Common IEC 60079 protection concepts include Ex db, Ex eb, Ex ia, Ex ib, Ex ic, Ex p, and protection concepts for combustible dust such as Ex tb. | Flameproof protection is commonly used for equipment that may contain an ignition source. Intrinsic safety is commonly applied to appropriately designed low-energy circuits. | Do not assume that a sealed housing alone is explosion protection. The complete certified construction, cable entries, joints, and installation method are important. |
| 4 | Check Gas Group and Temperature Class | Compare the site gas or vapor group and maximum surface-temperature requirement with the camera’s certified marking. | Gas groups may include IIA, IIB, and IIC. Temperature classes commonly range from T1 to T6, with T6 allowing the lowest maximum surface temperature. | More stringent groups and lower temperature limits require equipment with an equal or higher level of protection. | For example, equipment marked for IIC and T6 generally covers more demanding gas and temperature conditions than equipment marked only for IIA and T3, subject to the certificate. |
| 5 | Confirm EPL, Zone, and Dust Suitability | For dust-risk locations, verify the dust type, equipment protection level, maximum surface temperature, and protection against dust ingress. | Gas EPLs: Ga, Gb, Gc. Dust EPLs: Da, Db, Dc. Dust markings may include Ex t with a specified protection level and surface-temperature limit. | Zone 20 generally requires the highest dust protection level; Zones 21 and 22 require progressively different levels according to the risk assessment. | Ensure the certification covers combustible dust, not only flammable gas. Dust accumulation and cleaning procedures can affect the temperature risk. |
| 6 | Evaluate Ingress Protection and Environmental Conditions | Consider water, dust, salt spray, chemicals, vibration, impact, sunlight, corrosion, and the full operating-temperature range. | IP ratings are defined by IEC 60529. Common outdoor requirements include IP66; IP67 adds temporary immersion protection when specified by the manufacturer. | Outdoor process areas, washdown locations, coastal facilities, refineries, chemical plants, and dusty industrial environments. | IP protection is not a substitute for explosion protection. Select enclosure materials, coatings, seals, and mounting hardware for the actual environment. |
| 7 | Check Imaging, Installation, and Maintenance Needs | Assess resolution, low-light performance, infrared illumination, viewing angle, optical zoom, latency, network connection, power supply, mounting, and maintenance access. | Review the certified power input, approved cable glands, conduit requirements, equipment protection level, ambient-temperature range, and any certificate limitations. | Continuous monitoring of tanks, loading bays, pipelines, production areas, storage facilities, and perimeter zones. | Use only certified accessories and follow the installation manual. Maintenance, opening, cable replacement, and inspection must follow site permit and hazardous-area procedures. |