| 1 | Pressure class | Design pressure and maximum operating pressure | Select an ASME B16.34 Class 150, 300, 600, 900, 1500, or 2500 valve that exceeds the required pressure at the design temperature. | Chrome thickness does not increase the pressure class of the valve body or pressure boundary. | ASME B16.34 pressure-temperature ratings | Do not treat the class number as a universal pressure value. The allowable pressure depends on body material and temperature. |
| 2 | Design temperature | Minimum, normal, maximum, and upset temperatures | Use the pressure-temperature rating table for the exact valve material and the controlling temperature. | Confirm that the plating process, base material, seals, and lubrication system are suitable for the complete temperature range. | ASME B16.34; applicable material specifications | A rating acceptable at ambient temperature may be reduced at elevated temperature; low-temperature impact requirements may also apply. |
| 3 | Reference rating example | Approximate pressure at 100°F for carbon steel body material | Use the following values only as an initial reference for ASTM A216 WCB-type carbon steel; verify the certified material group and current standard edition. | The coating has no independent ASME pressure rating. | ASME B16.34 pressure-temperature tables | Illustrative ratings: Class 150: 285 psi; Class 300: 740 psi; Class 600: 1,480 psi; Class 900: 2,220 psi; Class 1500: 3,705 psi; Class 2500: 6,170 psi. Actual values must be confirmed from the selected material and standard edition. |
| 4 | Fluid compatibility | Water, oil, gas, steam, chemicals, abrasive or particle-laden media | Review fluid composition, concentration, pH, chloride content, velocity, solids content, and contamination risks. | Hard chrome can improve surface hardness and wear resistance, but it is not universally resistant to acids, chlorides, or aggressive chemicals. | Manufacturer chemical-compatibility data; ASTM coating test methods where specified | Specify the base metal, chrome type, coating thickness, substrate preparation, and chemical limits rather than requesting “chrome plated” alone. |
| 5 | Valve end connection | Flanged, threaded, socket-weld, or butt-weld piping system | Match the valve connection, nominal pipe size, facing, bore, wall thickness, and pressure class to the piping design. | Protect plated surfaces from impact, excessive tightening, welding heat, and installation damage. | ASME B16.5 for many flanges; ASME B16.25 for butt-weld ends; ASME B16.34 for valve requirements | Confirm dimensional compatibility and gasket selection before ordering, especially when changing pressure class or flange facing. |
| 6 | Leakage and testing | Required shutoff, shell integrity, and fugitive-emission performance | Define the valve test standard, seat leakage acceptance, test medium, duration, and documentation requirements. | Inspect the plating for pinholes, flaking, cracks, edge damage, and dimensional buildup that could affect sealing. | API 598 or the project-specified valve inspection and testing standard | Pressure testing must validate the complete assembled valve; coating inspection alone cannot demonstrate pressure-boundary integrity. |
| 7 | Operation and maintenance | Manual or automated operation, cycling frequency, accessibility, and maintenance interval | Check operating torque, actuator sizing, stem arrangement, installation orientation, drain or vent requirements, and spare-part availability. | Verify that repeated cycling, abrasive service, and contact with seats or packing will not prematurely wear the plated surface. | ASME B16.34; actuator and project maintenance specifications | Select plating for a defined wear or friction requirement, and establish repair or recoating limits before commissioning. |