| Feed-water salinity | Brackish water is commonly described as having about 1,000–10,000 mg/L total dissolved solids (TDS); actual classifications vary. | Salinity affects the pressure required, salt passage, recovery limits, and the overall treatment design. |
| Operating pressure | Many brackish-water RO applications operate at approximately 10–25 bar (about 145–363 psi), depending on feed chemistry and membrane selection. | RO must apply enough pressure to overcome the feed-water osmotic pressure. Higher salinity generally requires higher operating pressure. |
| Salt rejection | RO membranes commonly achieve roughly 95–99% salt rejection under specified test conditions; actual system performance varies. | Rejection determines how much dissolved salt passes into the permeate. System design and operating conditions affect the result. |
| Illustrative permeate TDS | At 2,000 mg/L feed TDS and 98% salt rejection, the estimated permeate TDS is about 40 mg/L. | This is a simplified calculation, not a guaranteed product-water value. Individual ions may pass through at different rates. |
| Water recovery | Recovery is often designed within a broad range of about 50–85%, depending on feed-water quality, pretreatment, and system configuration. | Higher recovery reduces concentrate volume but also increases the concentration of dissolved salts in the reject stream, which can raise scaling risk. |
| Scaling and fouling risk | Calcium carbonate, calcium sulfate, silica, iron, suspended solids, and organic matter may require control, depending on the source water. | Deposits and fouling can reduce permeate flow, increase pressure requirements, and lead to more frequent cleaning or membrane replacement. |
| Pretreatment needs | May include sediment filtration, cartridge filtration, pH adjustment, antiscalant dosing, iron or manganese removal, and disinfection management. | Pretreatment should be selected from a water analysis and designed to protect the membranes from particles, scale, and incompatible chemicals. |
| Energy demand | Energy use varies substantially with salinity, pressure, recovery, equipment efficiency, and system boundaries; brackish-water RO generally requires less pressure than seawater RO. | Lower feed-water salinity can reduce pumping requirements, but energy estimates should be based on the complete application and operating conditions. |
| Concentrate management | The reject stream contains concentrated dissolved salts and may also contain constituents removed during pretreatment. | Disposal or reuse options must comply with local requirements and be evaluated for site conditions and concentrate composition. |
| Best-fit applications | Common uses include groundwater desalination, industrial process water, and treatment of lower-salinity sources where dissolved salts must be reduced. | A brackish-water RO system can be a practical choice when source-water analysis confirms that its pressure, recovery, and pretreatment needs are suitable. |