| 01 | Profile A — Industrial General-Purpose | Single-phase, 100–240 VAC, 50/60 Hz | 10 VDC nominal | 5–50 A | Full-wave bridge with silicon diodes | Aluminum heat sink, short-circuit protection, screw terminals, forced or natural cooling options | Typically 80–92% | IEC 60146-1-1; RoHS; ISO 9001 manufacturing systems commonly specified | Control panels, battery charging, electroplating, automation equipment |
| 02 | Profile B — Compact PCB-Mount | 85–264 VAC, 47–63 Hz | 10 VDC regulated | 0.5–5 A | Bridge rectifier followed by high-frequency switching regulation | Low-profile PCB package, over-voltage protection, over-current protection, low standby consumption | Typically 78–88% | IEC 62368-1 or IEC 61558-1 application-dependent; RoHS; EMC testing commonly applied | Embedded controllers, instrumentation, smart meters, communication devices |
| 03 | Profile C — DIN-Rail Mounted | 100–240 VAC, 50/60 Hz | 10 VDC adjustable, typically ±10% | 2–20 A | Bridge rectification with regulated switching output | DIN-rail enclosure, LED status indicator, DC-OK relay option, thermal protection | Typically 84–94% | IEC 62368-1, IEC 61000-6-2, IEC 61000-6-4; RoHS and CE marking commonly targeted | Factory automation, PLC systems, sensors, machine control cabinets |
| 04 | Profile D — High-Current Industrial | Single-phase, 110–230 VAC, 50/60 Hz | 10 VDC nominal | 50–200 A | Heavy-duty diode bridge with smoothing reactor or capacitor bank | High surge capability, copper busbars, replaceable semiconductor modules, forced-air cooling | Typically 88–96% | IEC 60146-1-1; IEC 60529 enclosure protection where applicable; ISO 9001 quality systems | Electroplating lines, welding equipment, industrial battery systems, DC bus supplies |
| 05 | Profile E — Low-Ripple Precision | 100–240 VAC, 50/60 Hz | 10 VDC regulated | 1–15 A | Full-wave rectifier, active PFC option, post-regulation stage | Low output ripple, remote sensing, adjustable current limit, EMI filter | Typically 82–93% | IEC 61000-3-2, IEC 61000-6-2, IEC 61000-6-4; RoHS; production traceability often required | Laboratory equipment, test instruments, LED drivers, measurement systems |
| 06 | Profile F — Battery-Charging Rectifier | 90–264 VAC, 47–63 Hz | 10 VDC charging output | 2–30 A | Controlled rectifier or switching charger with constant-current/constant-voltage control | Float-charge mode, reverse-polarity protection, temperature compensation option, charge-status indication | Typically 85–94% | IEC 62477-1 or IEC 60335-2-29 depending on use; RoHS; EMC verification | Small battery packs, emergency lighting, access-control systems, backup power units |
| 07 | Profile G — Medical and Low-Leakage | 100–240 VAC, 50/60 Hz | 10 VDC regulated | 0.5–10 A | Isolated bridge rectifier with reinforced insulation and regulated output | Low leakage current, reinforced isolation, sealed enclosure options, low acoustic noise | Typically 80–90% | IEC 60601-1 may apply to medical electrical equipment; IEC 60601-1-2 for EMC; RoHS | Medical monitors, analytical instruments, laboratory devices, patient-care accessories |
| 08 | Profile H — Outdoor and Harsh-Environment | 100–240 VAC, 50/60 Hz | 10 VDC nominal | 2–25 A | Bridge rectifier with conformal-coated switching power stage | IP65 or higher enclosure options, surge protection, corrosion-resistant housing, wide temperature range | Typically 82–92% | IEC 60529; IEC 61000-4 surge and immunity tests; RoHS; environmental testing to IEC 60068 where specified | Outdoor lighting, surveillance equipment, telecom cabinets, solar-control systems |
| 09 | Profile I — Modular Parallel-Redundant | 90–264 VAC, 47–63 Hz | 10 VDC regulated | 10–60 A per module | High-frequency rectification with active current sharing | N+1 redundancy, hot-swap option, ORing protection, remote monitoring, replaceable modules | Typically 88–95% | IEC 62477-1; IEC 61000 series; RoHS; manufacturing traceability and burn-in testing commonly requested | Telecom power systems, data equipment, industrial control, critical infrastructure |
| 10 | Profile J — Cost-Optimized OEM | 176–264 VAC, 50/60 Hz | 10 VDC nominal | 1–20 A | Unregulated or lightly regulated silicon-diode bridge | Simple construction, compact enclosure, customizable terminals, economical production design | Typically 75–90% | IEC 60146-1-1 design reference; RoHS; CE and EMC documentation according to target market | Consumer appliances, simple control circuits, indicator systems, OEM subassemblies |