| Pump type | Fixed-displacement vane pump | Match the required design and control method; a variable-displacement pump is not automatically interchangeable. | Check the pump documentation and the machine’s hydraulic circuit. |
| Displacement | 25 cm³/rev | Match the original displacement or confirm that the machine can accommodate the resulting flow difference. | Compare cm³/rev on the nameplate or technical sheet. |
| Flow rate | About 37.5 L/min theoretical at 1,500 rpm for 25 cm³/rev | Provide the required flow at the actual operating speed and pressure; actual flow is lower than theoretical flow because of volumetric losses. | Estimate theoretical flow as displacement × rpm ÷ 1,000, then verify the rated flow data. |
| Continuous pressure | 160 bar operating requirement | Rated continuous pressure must meet or exceed the system’s maximum normal operating pressure. | Compare the pump’s continuous rating—not only its peak rating—with system pressure. |
| Peak pressure | Brief transients up to 180 bar | Allowable intermittent pressure and duration must cover the machine’s pressure spikes. | Check the manufacturer’s limits and the relief-valve setting; do not use peak rating as a continuous rating. |
| Operating speed | 1,500 rpm nominal | The normal and maximum drive speeds must remain within the replacement pump’s specified range. | Check motor speed, drive ratio, and pump minimum and maximum speeds. |
| Rotation direction | Clockwise, viewed from the shaft end | Match the required rotation; some pumps are directional and may be damaged if driven incorrectly. | Confirm the viewing convention and rotation marking in the documentation. |
| Mounting and shaft | Flange-mounted; keyed shaft | Mounting standard, pilot diameter, bolt pattern, shaft diameter, length, and connection type must fit the drive. | Compare dimensional drawings and coupling details, not just the pump’s external size. |
| Port layout and size | Separate inlet and outlet ports; sizes to be confirmed | Port locations, thread or flange standard, and flow-path orientation must suit the existing pipework. | Check port drawings and connection standards; avoid forcing mismatched fittings. |
| Hydraulic fluid and viscosity | Mineral hydraulic oil; ISO VG 32 or 46 may be used where specified by the system | The replacement must support the installed fluid and its viscosity across the actual operating-temperature range. | Check fluid type, viscosity limits, and seal compatibility in the pump documentation. |
| Inlet conditions | Flooded inlet, short suction line | Inlet pressure and suction-line losses must stay within the pump’s limits to reduce cavitation risk. | Check allowable inlet pressure, line size, fluid temperature, and installation height. |
| Temperature and seals | Operating range depends on fluid and seal material | The pump’s temperature limits and elastomers must be suitable for the fluid and ambient conditions. | Confirm fluid temperature, seal material, and stated operating limits. |