| Wire construction | Many individually insulated copper strands, gathered and transposed or braided into a bundle | Strand insulation and transposition help distribute current among strands and reduce the effects of skin and proximity currents. | Confirm that the construction is genuinely transposed; a simple bundle of insulated strands may not provide equivalent current sharing. |
| Copper skin depth at 20 kHz | Approximately 0.46 mm | Current tends to crowd toward the conductor surface as frequency rises, increasing AC resistance. | Use skin depth as a design reference, not as a guarantee of low loss; winding geometry and nearby magnetic fields also matter. |
| Copper skin depth at 100 kHz | Approximately 0.21 mm | Thinner strands can reduce current crowding within each strand at this frequency. | Compare strand diameter with the operating-frequency skin depth, then verify losses under the actual waveform and winding conditions. |
| Copper skin depth at 1 MHz | Approximately 0.066 mm | At this frequency, relatively small strand diameters may be needed to limit skin-effect losses within individual strands. | Very fine strands can increase insulation fraction, handling difficulty, and cost. Check both electrical and mechanical requirements. |
| Strand diameter | Common designs use strands from tens to several hundred micrometres; the suitable value depends on frequency and construction. | Smaller strands can reduce strand-level skin effect, but do not by themselves eliminate proximity effect or other AC losses. | Choose strand size with the frequency spectrum, current, bundle size, and winding-field distribution in mind. |
| Number of strands | From a few dozen to several thousand, depending on total copper area and strand size | More strands can provide the required copper area while keeping each strand small, but may make the bundle larger and harder to terminate. | Specify total copper cross-sectional area as well as strand count; strand count alone is not a measure of current capacity. |
| Common applications | High-frequency transformers, inductors, resonant converters, wireless-power coils, and induction-heating equipment | These applications can have significant AC resistance due to high frequency, strong magnetic fields, or both. | Consider litz wire when measured or modeled AC losses justify its added complexity; it is not automatically the best choice for every high-frequency winding. |
| Insulation and termination | Strand enamel, bundle wrapping, and application-specific end preparation | Insulation affects bundle fill, voltage capability, thermal behavior, and the reliability of electrical connections. | Check temperature class, voltage requirements, winding space, and the required stripping or soldering process before selecting a construction. |
| Thermal and loss verification | Evaluate at the intended frequency, waveform, RMS current, winding layout, and operating temperature | Litz wire can reduce some AC losses, but total loss also includes copper DC resistance, proximity effect, core loss, and connection losses. | Use an appropriate loss model or prototype measurement, and verify temperature rise in the final assembly. |