| Commercial Quality | DX51D+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z275 | 100–275 g/m² total both sides | 0.40–3.00 mm | Good general-purpose formability; suitable for profiling, bending, and light fabrication. | Roofing panels, wall cladding, ducts, general sheet-metal work |
| Deep-Drawing Quality | DX52D+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z275 | 100–275 g/m² total both sides | 0.50–2.50 mm | Higher formability than commercial-quality material; intended for more demanding pressing operations. | Pressed panels, appliance parts, formed enclosures |
| Extra Deep-Drawing Quality | DX53D+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z275 | 100–275 g/m² total both sides | 0.50–2.00 mm | Designed for complex forming; requires controlled tooling and forming practice. | Automotive components, complex pressed parts, deep-drawn housings |
| Structural Quality | S220GD+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z600 | 100–600 g/m² total both sides | 0.50–3.00 mm | Minimum specified yield strength of 220 MPa; suitable for structural cold forming. | Building frames, purlins, structural profiles, support members |
| Structural Quality | S350GD+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z600 | 100–600 g/m² total both sides | 0.60–3.00 mm | Minimum specified yield strength of 350 MPa; combines higher strength with moderate formability. | Roofing and wall systems, framing components, industrial structures |
| Structural Quality | S550GD+Z | EN 10346 | Hot-dip galvanized sheet or coil | Z100–Z600 | 100–600 g/m² total both sides | 0.60–3.00 mm | Minimum specified yield strength of 550 MPa; high-strength option for weight reduction. | Light-gauge structural framing, solar support components, high-strength profiles |
| Commercial Quality | CS Type B | ASTM A653/A653M | Hot-dip galvanized sheet or coil | G30–G90 | 0.30–0.90 oz/ft² total both sides Approximately 92–275 g/m² | 0.30–3.40 mm | General-purpose commercial-quality steel for forming and fabrication. | Roofing, siding, HVAC components, general fabrication |
| Structural Quality | SS Grade 50 | ASTM A653/A653M | Hot-dip galvanized sheet or coil | G60–G90 | 0.60–0.90 oz/ft² total both sides Approximately 183–275 g/m² | 0.45–3.40 mm | Minimum specified yield strength of 50 ksi, approximately 345 MPa; suitable for structural applications. | Structural panels, framing, construction components, formed sections |
| Automotive Quality | SGMCC | JIS G3302 | Hot-dip galvanized sheet or coil | Z12–Z27 | 120–275 g/m² total both sides | 0.40–2.30 mm | General commercial-quality galvanized steel with controlled surface quality and formability. | Automotive parts, appliance panels, formed sheet-metal components |
| Structural Quality | SGH540 | JIS G3302 | Hot-dip galvanized sheet or coil | Z12–Z35 | 120–350 g/m² total both sides | 0.60–3.20 mm | High-strength structural grade with a minimum tensile strength of approximately 540 MPa. | Structural profiles, construction equipment, industrial components |
| Zinc Coating | Regular Spangle | Available under ASTM, EN, and JIS product standards | Hot-dip galvanized sheet or coil | Specified by coating mass or designation | Selected according to corrosion-resistance requirements | Grade-dependent | Visible zinc crystal pattern; suitable where appearance is acceptable and standard corrosion protection is required. | Roofing, cladding, structural profiles, general fabrication |
| Zinc Coating | Minimized Spangle | Available under selected ASTM, EN, and JIS product standards | Hot-dip galvanized sheet or coil | Specified by coating mass or designation | Selected according to corrosion-resistance requirements | Grade-dependent | Reduced visible spangle and more uniform surface appearance than regular spangle material. | Visible architectural panels, appliances, painted components |
| Surface Treatment | Chromate-Free Passivation | Customer specification and applicable product standard | Galvanized sheet or coil | Used with Z, G, or equivalent coating designations | Does not replace the metallic zinc coating | Grade-dependent | Helps reduce wet-storage staining; preferred where restricted-substance requirements apply. | Indoor storage, appliances, automotive and environmentally controlled applications |
| Surface Treatment | Oiled Surface | Customer specification and applicable product standard | Galvanized sheet or coil | Used with the selected zinc coating | Oil quantity is specified separately by the purchaser | Grade-dependent | Temporary corrosion protection during storage and transportation; oil must be considered before painting or bonding. | Export shipments, fabrication stock, industrial processing |
| Dimensional Tolerance | Standard Tolerance | ASTM A924/A924M, EN 10143, or JIS G3302 as applicable | Sheet or coil | Not applicable | Not applicable | Typical ordered thickness: 0.40–3.20 mm | Thickness, width, flatness, camber, and length tolerances depend on the governing standard and ordered class. | International procurement and general manufacturing |
| Supply Dimensions | Common Width Options | Subject to mill capability and purchase specification | Coil or cut-to-length sheet | Any compatible coating designation | Any compatible coating mass | Common widths: 914, 1000, 1220, and 1250 mm | Custom widths and cut lengths may be specified; availability depends on thickness, grade, and coating combination. | Roofing, roll forming, fabrication, construction projects |
| Technical note: Coating designations are not directly interchangeable across standards. Confirm the required standard, grade, coating mass, surface condition, dimensional tolerance, inspection requirements, and test certificate before purchase. Zinc coating mass values are normally stated as the total for both surfaces unless the applicable standard specifies otherwise. |