| 1 | Cam-lock female coupler with hose shank | Fast connection of liquid discharge hoses, transfer lines, tanks, pumps, and temporary systems | 25, 38, 50, 63, 75, 100, 125 and 150 mm; exact sizes depend on the coupling series | Stainless steel, polypropylene, aluminum, or ductile metal; elastomer gasket selected for the medium | Cam arms lock against an adapter; sealing is normally provided by a replaceable gasket | Often approximately 6–16 bar, but must be confirmed by size, material, temperature, and manufacturer testing | Verify EN 14420-7 dimensions and interchangeability; confirm hose-tail geometry and working-pressure marking | EU: check whether the complete assembly falls under PED 2014/68/EU; U.S.: verify applicable hose, material, and workplace requirements; other markets may require local pressure documentation | General-purpose liquid transfer where frequent tool-free connection is important |
| 2 | Cam-lock male adapter with threaded end | Connecting discharge hoses to pumps, manifolds, valves, filters, and fixed pipework | Cam-lock sizes commonly from 25 to 150 mm; thread sizes vary from approximately 1 to 6 in | Stainless steel, aluminum, polypropylene, or plated carbon steel where permitted by the medium | Cam adapter on one side; male or female pipe thread on the other; thread sealant may be required | Usually limited by the lower-rated threaded component; verify pressure at operating temperature | EN 14420-7 for cam interface; ISO 228-1 applies only where the product uses compatible parallel pipe threads | Do not assume ISO 228-1 compatibility with tapered NPT or other national thread systems; request thread inspection records and drawings | Projects requiring quick hose removal from threaded equipment or mixed piping layouts |
| 3 | Dry-disconnect coupler | Hazardous, costly, sensitive, or environmentally controlled liquids where spillage must be minimized | Commonly 25–100 mm; larger sizes are available in specialized designs | Stainless steel or chemically resistant engineered materials with application-specific seals | Valved male and female halves open only when correctly connected; self-sealing design reduces residual leakage | Often approximately 10–25 bar, depending on design, size, medium, and temperature | EN 14420-7 does not automatically cover every dry-disconnect design; obtain the specific product standard, test report, and leak-rate data | EU pressure-equipment assessment may apply to the complete pressure accessory; chemical, food, pharmaceutical, or hazardous-area rules may add requirements | Chemical transfer, fuel handling, environmental services, and high-consequence liquid operations |
| 4 | Threaded hygienic coupler | Food, beverage, dairy, cosmetic, and pharmaceutical discharge lines requiring cleanable connections | Typically 25–100 mm tube outside diameters; connection dimensions must match the hygienic system | Austenitic stainless steel with EPDM, silicone, PTFE, or other documented hygienic sealing materials | Sanitary clamp, union, or hygienic threaded connection; smooth internal surfaces and flush seals are preferred | Commonly approximately 6–16 bar; confirm pressure after cleaning, sterilization, and temperature cycles | EN 14420-7 is not a hygienic-design standard; verify the applicable sanitary tube, surface-finish, elastomer, and cleanability requirements | EU: food-contact compliance may be required; U.S.: check FDA food-contact status for wetted materials; request migration and traceability documents | Buyers prioritizing cleanability, material traceability, and low contamination risk |
| 5 | Flanged hose coupler | Large-diameter discharge, dredging, dewatering, slurry, marine, and fixed pump installations | Approximately 50–300 mm or larger; flange drilling must match the mating equipment | Stainless steel, carbon steel, ductile iron, or reinforced polymer construction depending on corrosion and abrasion demands | Bolted flange connection with a gasket; alignment, bolt grade, bolt torque, and gasket selection are critical | Pressure classes commonly range from PN 6 to PN 16 in metric systems; higher ratings require specific design verification | EN 14420-7 generally does not define the complete flange system; verify the applicable flange dimensions, drilling, pressure class, and gasket standard | Confirm PN, Class, or other regional flange systems before ordering; do not mix drilling patterns without an approved adapter | High-flow systems where mechanical strength and stable alignment are more important than rapid tool-free coupling |
| 6 | Cam-lock coupler with locking safety feature | Mobile discharge lines exposed to vibration, hose movement, accidental cam-arm release, or frequent handling | Commonly 38–100 mm; select size based on required flow and hose inside diameter | Stainless steel or other application-approved metals; safety pins, clips, or locking levers must resist corrosion | Cam-lock interface with secondary arm retention, locking pin, or accidental-release prevention feature | Use the lower pressure rating of the coupler, hose, gasket, and safety device; dynamic loading requires additional review | Verify EN 14420-7 interface dimensions plus documented retention, pull-off, vibration, and pressure tests for the safety feature | Workplace safety rules vary by country; a product certificate does not replace a site risk assessment, hose restraint, or safe operating procedure | Transport, construction, agriculture, marine service, and other installations with movement or vibration |
| 7 | Composite or lightweight polymer coupler | Water, wastewater, irrigation, low-to-moderate duty chemical service, and applications where low weight reduces handling effort | Commonly 25–150 mm; available sizes depend on the polymer system and reinforcement design | Polypropylene, glass-reinforced polymer, thermoplastic composite, or polymer-lined metal | Cam-lock, threaded, or flanged connection; chemical compatibility and thermal expansion must be checked | Often approximately 4–10 bar, with allowable pressure typically decreasing as temperature increases | Verify whether the complete design has been tested to EN 14420-7; confirm UV, impact, vacuum, temperature, and chemical-resistance data | For potable water or food contact, obtain region-specific material approval; environmental and fire requirements may apply to special installations | Buyers seeking corrosion resistance, portability, and lower total handling weight |